Immediate placement, immediate loading of single implant in fresh extraction socket


1 Department of Paediatric and Preventive Dentistry, Jaipur Dental College, Jaipur, Rajasthan, India
2 Consultant, Wisdom Dental Clinic, Jaipur, Rajasthan, India
3 Senior Consultant, Wisdom Dental Clinic, Jaipur, Rajasthan, India
4 Department of Paediatric and Preventive Dentistry, RUHS College of Dental Science, Jaipur, Rajasthan, India
5 Department of Conservative and Endodontics Dentistry, Government Dental College, Indore, Madhya Pradesh, India

Date of Web Publication13-Feb-2020

Correspondence Address:
Dr. Gaurav Gupta
Sector - 10, Plot Number - 15, Vidhyadhar Nagar, Jaipur, Rajasthan
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ccd.ccd_565_18

Rights and Permissions
   Abstract 

Smile is an important factor which enhances our beauty. A well-formed complete smile is the basis for facial esthetics. To bring out a beautiful smile, a full set of dentition is necessary. The replacement of missing teeth with implant-borne restorations has become the treatment of choice these days. According to recent reports, the successful implant placement in fresh extraction socket is made possible by modifying the surface of implants. The present case report highlights on the high survival rate of immediate implant loading placed successfully in fresh extraction socket which was confirmed by implant stability quotient (resonance frequency analysis) to assess implant stability noninvasively.

Keywords: Dental implant, immediate loading, implant stability quotient


How to cite this article:
Gupta G, Gupta D K, Gupta N, Gupta P, Rana KS. Immediate placement, immediate loading of single implant in fresh extraction socket. Contemp Clin Dent 2019;10:389-93

How to cite this URL:
Gupta G, Gupta D K, Gupta N, Gupta P, Rana KS. Immediate placement, immediate loading of single implant in fresh extraction socket. Contemp Clin Dent [serial online] 2019 [cited 2020 Feb 26];10:389-93. Available from: http://www.contempclindent.org/text.asp?2019/10/2/389/278164


   Introduction Top


Loss of tooth in the esthetic zone is a traumatic experience with or without compromise in phonetics. Therefore, the most challenging situation bothering a clinician is the implant-supported single tooth replacement at the earliest.

Conventionally, 3–4 months of healing period is required for the maturation of extraction socket. Taking into account the prosthetic treatment, patients have to wait for >6 months for the replacement of a lost tooth.[1]

Efforts have been made to decrease the treatment period by focusing on the approaches such as early or immediate loading following implant placement,[2] immediate implant placement in fresh extraction site,[3] and immediate implant placement and early or immediate loading.[2]

Implant placement in postextraction sites in a single-session surgery shows high success rates, ranging from 92.7% to 98%, depending on the observed clinical records.[4],[5] A Cochrane review shows that patients have higher satisfaction levels in case of placement techniques in postextraction implants, when compared to conventional techniques in which complete healing is expected in postextraction sites. As the alveolar bone is preserved, enhanced esthetic results can be guaranteed. Postextraction implants are biologically and functionally efficient as they also reduce treatment time.

Primary implant stability still remains an essential requisite to obtain implant success both in delayed and postextractive methodologies.[6] During the osseointegration process, primary mechanical stability is gradually replaced by biological stability. When the healing phase is completed, primary mechanical stability is totally replaced by biological stability.[7]

In this case report, the harmony of soft and hard tissue was preserved by immediate implant placement and immediate loading in the anterior maxilla in fresh extraction socket.


   Case Report Top


A 38-year-old female patient came to our clinic with a history of trauma 4 days back in the upper front tooth region, and mobile tooth segment was splinted by composites on affected and adjacent crowns by local dentist [Figure 1]. X-ray revealed that tooth fractured at the middle third part of root [Figure 2]. The patient was conscious about her esthetics and wanted the earliest possible solution. Because of the inability of the patient to come back frequently, various options of the implant-retained prosthesis were discussed, upon which the patient gave consent for immediate implant placement and immediate loading in fresh extraction socket.
Figure 1: Fractured tooth splinted with composite

Click here to view
Figure 2: Intraoral periapical revealed fractured root at middle third

Click here to view


Following administration of local anesthesia, the fracture tooth was atraumatically removed with the help of periotomes [Figure 3] and [Figure 4]. The resulting extraction socket was evaluated for osseous defects. All four walls were found intact [Figure 5]. The extraction socket was thoroughly cleaned. As there was limitation of time and resources, surgical template could not be prepared.
Figure 3: Atraumatic extraction using periotomes

Click here to view
Figure 4: Fractured tooth removed

Click here to view
Figure 5: Atraumatic tooth extraction without flap reflection resulted in well-preserved bone and soft tissue architecture

Click here to view


Certain factors which were important for the better prognosis of immediate placement and immediate loading were:

  1. Atraumatic extraction: Extraction has to be done in minimal invasive manner, both at hard and soft tissue levels so as to restore the natural esthetics in very short span of time. Therefore, periotomes were skillfully used for the same
  2. Strategic implant placement is necessary to achieve adequate amount of primary stability: Insertion torque is the key factor in deciding whether or not to load immediately. The implant should be well anchored in the bone and able to withstand a torque minimum of 35 Ncm for the abutment screws securing, etc.
  3. Implant selection: Tapered-screw implant with enhanced or modified grooves, an osseoconductive surface, and of sufficient length (a minimum of 10–13 mm)
  4. Retrievable prosthesis: To compensate for any soft tissue recession, we might need to alter the crown at later stages, and for that, we need to place screw hole to be lingually so that the crown can be retrieved, modified, and placed back, if at all required.


Considering above-mentioned points, osteotomy was started in the fresh extraction socket. A periodontal probe was kept on the incisal edges from the lateral incisor of the same side to the central incisor of the other side. Osteotomy was started from the lingual side of the probe so as to check the angulation of drills, which will result in favorable position of the screw hole in prosthesis. For achieving good primary stability, osteotomy was done around 2.5 mm apical to the extraction socket to gain anchorage from nasal cortex. Length of the extracted root was around 11 mm [Figure 6].
Figure 6: Strategic osteotomy

Click here to view


Nobel Biocare active implant measuring 4.5 mm × 13 mm in dimension was placed with insertion torque of 50 Ncm [Figure 7] and [Figure 8]. Immediately after this, implant level impression was made and healing abutment was placed [Figure 9] and [Figure 10].
Figure 7: Immediate implant placement

Click here to view
Figure 8: Insertion torque more than 50 Ncm

Click here to view
Figure 9: Open tray impression coping

Click here to view
Figure 10: Healing abutment placed on the day of surgery and after 48 h

Click here to view


After 48 h, stability of implant was measured by Osstell implant stability quotient (ISQ) meter and 79 readings were obtained which state it to be highly stable [Figure 11]. Cement-retained porcelain-fused metal crown was delivered with screw hole present on the lingual side [Figure 12] and [Figure 13]. Satisfactory final outcome was achieved in short span of 2 days in a perceive manner.
Figure 11: Implant stability quotient-Osstell

Click here to view
Figure 12: Uneventful healing with excellent soft tissue architecture

Click here to view
Figure 13: Screw retained crown delivered

Click here to view


The patient came back after 1 year of follow-up. Clinical examinations revealed excellent soft tissue harmony. X-ray also revealed minimal amount of bone resorption around the implant [Figure 14] and [Figure 15].
Figure 14: Follow-up after 1 year

Click here to view
Figure 15: X-ray at the time of delivery and at 1-year follow-up with minimal bone resorption

Click here to view



   Discussion Top


For missing anterior teeth, immediate implant and early loading is a good treatment option because its success rate in the maxilla is 90%–95.5% and in the mandible is 93%–99%.[8]

Indication for placement of the immediate implant is extraction due to trauma, endodontic lesion, root fracture, root resorption, root perforation, unfavorable crown-to-root ratio (not due to periodontal loss), and bony walls of alveolus are still intact.[9] Contraindications include presence of active infection, insufficient bone (<3 mm) beyond the tooth socket apex for initial implant stability, and wide and/or long gingival recession.

Implant placement site was properly evaluated and assessed before extraction. A proper plan was made which included soft tissue treatment protocol and set of well-defined esthetic goals.[10] After the treatment, the soft tissue architecture remained stable with preservation of adequate attached gingiva throughout the healing period of the implant as well as after final prosthesis delivery. It was esthetically pleasing and biologically sound results were obtained.

Unlike the conventional scenario, we do not have to follow the traditional drills and protocols in fresh extraction socket. This is easily explainable when considering the dimensional discrepancies between the implant itself and the implant bed prepared with the two different drilling protocols.[11] The results showed that implant installation with the drill only protocol resulted in increased primary stability with high ISQ values as evaluated with resonance frequency analysis and significantly increased average maximum insertion torque values compared with implant installation with the standard drilling protocol.

Under three parameters, the prospective implant site was evaluated to predict the peri-implant esthetic outcome; these are tooth position and shape, form and biotype of the periodontium, and position of osseous crest.[12]

A surgeon may wish to consider loading the newly placed implant immediately or early when any one of the following conditions exists at implant site: (a) When primary stability is obtained. (b) Site can accommodate implant with a length of atleast 13 mm or minimum 3 mm of apical bone present. (c) Diameter of head of the implant closely matches the mesiodistal width of coronal aspect of the socket. (d) No need of bone augmentation procedures. (e) Once placed. the implant can be completely protected from functional and occlusal forces.[13]

The initial stability of the implant is essential for early/immediate loading. The minimum insertion screw should be equal or superior to 32 N/cm with micro-movement not exceeding 150 μm.[14] In this case report, primary stability was achieved with proper insertion torque and bone grafting was not required as the implant diameter closely matches the socket dimension.

In the present scenario, implant stability (ISQ value) was determined by the Osstell apparatus. A substantial increase or decrease in implant stability could be detected with this method that otherwise could not be clinically perceived. The factors affecting the readings are effective implant length, bone quality and quantity, implant length, diameter, and shape. Effective implant length is the length of the exposed threads and abutment height.[15]

The gingival esthetic achieved was satisfactory. Studies have confirmed that immediate loading will produce excellent gingival esthetics. Although in this study only two patient visits were needed to achieve this result, our real goal is to show the potential to reduce time and improve patient satisfaction.


   Conclusion Top


The present study achieved its early result with the immediate implants placed in the extraction socket. The minimal surgery used in this study enabled slight postoperative discomfort and uneventful healing. The complications were mild and statistically nonsignificant. Hence, this case report supports successful implant placement with desired stability by immediate loading in the fresh extraction socket.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Brånemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses, I: Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100.  Back to cited text no. 1
    
2.
De Rouck T, Collys K, Cosyn J. Immediate single-tooth implants in the anterior maxilla: A 1-year case cohort study on hard and soft tissue response. J Clin Periodontol 2008;35:649-57.  Back to cited text no. 2
    
3.
Ataullah K, Chee LF, Peng LL, Tho CY, Wei WC, Baig MR, et al. Implant placement in extraction sockets: A short review of the literature and presentation of a series of three cases. J Oral Implantol 2008;34:97-106.  Back to cited text no. 3
    
4.
Grunder U, Polizzi G, Goené R, Hatano N, Henry P, Jackson WJ, et al. A3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants. Int J Oral Maxillofac Implants 1999;14:210-6.  Back to cited text no. 4
    
5.
Tolman DE, Keller EE. Endosseous implant placement immediately following dental extraction and alveoloplasty: Preliminary report with 6-year follow-up. Int J Oral Maxillofac Implants 1991;6:24-8.  Back to cited text no. 5
    
6.
Bhola M, Neely AL, Kolhatkar S. Immediate implant placement: Clinical decisions, advantages, and disadvantages. J Prosthodont 2008;17:576-81.  Back to cited text no. 6
    
7.
Raghavendra S, Wood MC, Taylor TD. Early wound healing around endosseous implants: A review of the literature. Int J Oral Maxillofac Implants 2005;20:425-31.  Back to cited text no. 7
    
8.
Uribe R, Peñarrocha M, Balaguer J, Fulgueiras N. Immediate loading in oral implants. Present situation. Med Oral Patol Oral Cir Bucal 2005;10 Suppl 2:E143-53.  Back to cited text no. 8
    
9.
Douglass GL, Merin RL. The immediate dental implant. J Calif Dent Assoc 2002;30:362-5.  Back to cited text no. 9
    
10.
Kolte DV. Immediate implant placement after extraction of mandibular molars: Report of 3 cases. J Dent Med Sci 2013;5:46-53.  Back to cited text no. 10
    
11.
Stavropoulos A, Cochran D, Obrecht M, Pippenger BE, Dard M. Effect of osteotomy preparation on osseointegration of immediately loaded, tapered dental implants. Adv Dent Res 2016;28:34-41.  Back to cited text no. 11
    
12.
Paolantonio M, Dolci M, Scarano A, d'Archivio D, di Placido G, Tumini V, et al. Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man. J Periodontol 2001;72:1560-71.  Back to cited text no. 12
    
13.
Hahn J, Babbush CA. The Art and Science. Immediate implant placement after extraction: Contemporary materials and techniques. 2nd ed. United States of America: W.B. Saunders; 2001. p. 305-34.  Back to cited text no. 13
    
14.
Del Fabbro M, Testori T, Francetti L, Taschieri S, Weinstein R. Systematic review of survival rates for immediately loaded dental implants. Int J Periodontics Restorative Dent 2006;26:249-63.  Back to cited text no. 14
    
15.
Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7.  Back to cited text no. 15
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11], [Figure 12], [Figure 13], [Figure 14], [Figure 15]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed43    
    Printed0    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal