Contemporary Clinical Dentistry
   
  Home | About us | Editorial board | Search
Ahead of print | Current Issue | Archives | Advertise
Instructions | Online submission| Contact us | Subscribe |

 

Login  | Users Online: 2197  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 

ORIGINAL ARTICLE
Year : 2019  |  Volume : 10  |  Issue : 2  |  Page : 220-225

Comparison of the depth of cure of flowable composites polymerized at variable increment thicknesses and voltages: An In vitro study


1 Department of Operative Dentistry, Jinnah Medical and Dental College, Karachi, Pakistan
2 Department of Operative Dentistry, Aga Khan University Hospital, Karachi, Pakistan

Correspondence Address:
Dr. Muhammad Hasan Hameed
Department of Surgery, JHS Building 1st Floor Dental Clinics, Aga Khan University Hospital, P.O Box 3500, Stadium Road, Karachi 74800
Pakistan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ccd.ccd_635_18

Rights and Permissions

Objectives: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). Materials and Methods: Each sample of the composite material was packed in a mold of 2 mm, 4 mm, and 6 mm and curing light (quartz tungsten halogen) of optimal intensity was exposed for 20 s at 2 different voltages on each specimen. After curing, the specimens were removed and the composite on the nonexposed end was scraped with a plastic instrument. The remaining composite thickness was measured using a digital Vernier caliper. The reading was divided by half to follow the ISO 4049 method. Independent sample t-test, one-way ANOVA, and linear regression analysis were applied. Level of significance was kept at 0.01. Results: The mean DOC of SDR and Filtek were 1.93 ± 0.82 and 1.77 ± 0.65 mm. Lowering the voltage from 220 to 180 volts reduced the depth of Filtek from 1.87 ± 0.74 to 1.67 ± 0.54 mm, whereas the DOC of SDR remained unchanged at 1.93 mm at the two voltages. The adjusted R2 for the depth of cure was 0.93 when the increment thickness, voltage, and restorative material were taken together in the regression model. Conclusions: There was no statistically significant difference between SDR and Filtek for the depth of cure at 2 and 4 mm increments. However, at 6 mm increment, the SDR cured significantly deeper than the Filtek. Around 91% variation in the depth of cure of these composites materials is explained by increment thickness alone.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed37    
    Printed0    
    Emailed0    
    PDF Downloaded5    
    Comments [Add]    

Recommend this journal