Overdenture locator attachments for atrophic mandible


1 Department of Prosthodontics, College of Dental Science, Amargadh, India
2 Department of Oral and Maxillofacial Surgery, Manubhai Dental College and Hospital, Vadodara, Gujarat, India

Date of Web Publication17-Dec-2013

Correspondence Address:
Neerja Mahajan
3, Navrang Compound, Opposite Vamil Park, Gotri Road, Vadodara - 390 021, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0976-237X.123060

Rights and Permissions
   Abstract 

Implant-supported overdentures provide a good opportunity for dentists to improve oral health and quality-of-life of patients. Atrophic mandible poses a significant challenge to successful oral rehabilitation with dental implants. In this article, the fabrication of lower overdenture by two narrow platform implants is described with dual retentive, resilient, self-locating locator attachment system. The locator attachment system has the lowest profile in comparison with the ball and bar attachments and is versatile up to 40΀ of divergence between two implants. By using locators as attachments, we can meet functional, economic and social expectation of patients with ease and satisfaction.

Keywords: Implants, locators attachments, overdentures


How to cite this article:
Mahajan N, Thakkur RK. Overdenture locator attachments for atrophic mandible. Contemp Clin Dent 2013;4:509-11

How to cite this URL:
Mahajan N, Thakkur RK. Overdenture locator attachments for atrophic mandible. Contemp Clin Dent [serial online] 2013 [cited 2019 Jun 16];4:509-11. Available from: http://www.contempclindent.org/text.asp?2013/4/4/509/123060


   Introduction Top


A common condition in geriatrics patients is the occurrence of edentulism. According to the United Nations Population Division (UN 2011), the share of India's population aged 60 and older is projected to climb from 8% in 2010 to 19% in 2050. One therapeutic approach directed at improving oral function in elderly is use of implant supported overdentures.

According to McGill and York consensus statements it is accepted that the two implant overdenture is not the gold standard of implant therapy, it is the minimum standard that should be sufficient for most people, taking in account performance, patient satisfaction, cost and clinical time. [1] The use of two interforaminal implants with an overdenture can provide long-term neuromuscular benefits for edentulous patients. [2]


   Case Report Top


A 68-year-old female patient reported with major complaint of loose lower complete denture prosthesis. The patient had been wearing a denture for the past 15 years and had a complaint of loose mandibular dentures for the last 5 years. On intraoral examination, the mandibular ridge was found to be severely resorbed. A thorough medical and dental history of the patient was recorded. As per procedure, physician's consent was taken besides doing routine blood investigation and tests.

Maxillary and mandibular study models were made. Orthopantomograph [Figure 1] and Dentascan was undertaken to assess the bone for selection of implants. Since the old denture of the patient was not appropriate for implant supported prosthesis, a new prosthesis was fabricated for the patient in accordance with the physiologic and functional aspects. Dentascan and lower denture were used to fabricate surgical stent. The Noble Active narrow platform implants; size 3.5 mm × 10 mm and 3.5 mm × 13 mm [Figure 2] were placed by surgically raising flap in canine to canine region. The knife edge ridge in the anterior region was flattened and basal bone improved. Standard post-operative surgical protocol was maintained and patient was asked not to use lower denture for 3 weeks. After 3 weeks, lower denture was locally relined with soft liner Mollosil Detax Germany.
Figure 1: Orthopantomograph showing severe mandibular atrophy

Click here to view
Figure 2: Orthopantomograph showing osseointegrated implants placed in the selected sites

Click here to view


After 6 months of the integration period, a definitive prosthodontic therapy was started by exposing the cover screws of implants. 5 mm flared Noble active healing abutments were placed to establish per mucosal seal. After 2 weeks, healing abutments were removed and depth measurements from the implant platforms to the most coronal aspect of the surrounding gingival levels were taken with the help of World Health Organization periodontal probe. Locator Implant Abutment height was computed by measuring the total soft-tissue depth and subtracting 0.5 mm for the platform shifting area of noble active implant.

In the above case, on one side 3 mm and other side 4 mm (Zest Anchors) locator abutment was placed [Figure 3] with the help of a special gold plated Abutment Driver. The abutments were tightened to 25-30 N with a torque wrench. The plastic resilient male caps with the metal housing can be processed into the denture by indirect laboratory technique or can be directly picked chair side. This allows denture to be snapped into the locator abutments. The chairside pick-up procedure is same as ball attachments. White blockout spacer or rings [Figure 4] and black processing male are provided by the manufacturer for ease in procedure. In the above procedure, chair side pick-up procedure with auto polymerizing resin was performed and blue male inserts were given to patient for initial few months [Figure 5].
Figure 3: Locator abutments

Click here to view
Figure 4: Locator abutments with White blockout ring/spacer

Click here to view
Figure 5: Tissue surface of the mandibular denture with retentive locator inserts

Click here to view


The retention can be increased gradually by changing to higher retentive caps, according to individual patient's usage and needs. These plastic resilient caps can be easily changed chairside during a recall appointment with Locator core tool. The angulation between implants can be measured with angle measurement guide which helps in the selection of specific male resilient cap.


   Discussion Top


This procedure allows fabrication of lower overdenture with Locator Attachments, which have the highest retention and stability followed by ball and then finally magnets as recommended by Sadig. [3]

The study by Cordaro et al. concluded that the clinicians found better hygienic conditions and soft-tissue health in locator group. [4]

Vere et al. recommended usage of locator system because the problems associated with these prostheses are usually simple to resolve chairside. [5]

According to Cakarer et al. it was found that the locator system showed superior clinical results than the ball and the bar attachments. [6] This was further supported by a clinical study conducted by El-Sheikh et al. They came to a conclusion that the use of two narrow bone level implants with locator attachments appears predictable and can adequately support an overdenture in cases of mandibular atrophy. [7]

Although ridge augmentation can help to restore ridge volume, grafting procedures can significantly increase patient morbidity, costs and treatment time. [8],[9],[10] So this clinical treatment avoids extensive surgical procedure.

Patient must maintain standard protocol of overdenture hygiene and follow-up visits. Posterior bone loss can be an issue, which requires relining procedure of the lower denture. Male cap might require changing in case of loss of retention, which can be carried out by simple chair side procedure.


   Conclusion Top


This article has described a simple, cost-effective, non-invasive and more retentive locator attachment overdenture treatment plan for an atrophic mandible. This treatment prevents the further resorption of residual alveolar ridge, requires less clinical time. Above all, it delivers greater patient satisfaction by giving a comfortable and stable prosthesis that provides better function.

This particular attachment system is relatively new as compared to the bar and ball and magnetic attachments. Further long-term prospective studies will certainly be required to confirm the encouraging results from this clinical case.

 
   References Top

1.Thomason JM, Kelly SA, Bendkowski A, Ellis JS. Two implant retained overdentures - A review of the literature supporting the McGill and York consensus statements. J Dent 2012;40:22-34.  Back to cited text no. 1
[PUBMED]    
2.Spitzl C, Pröschel P, Wichmann M, Heckmann S. Long-term neuromuscular status in overdenture and complete denture patients with severe mandibular atrophy. Int J Oral Maxillofac Implants 2012;27:155-61.  Back to cited text no. 2
    
3.Sadig W. A comparative in vitro study on the retention and stability of implant-supported overdentures. Quintessence Int 2009;40:313-9.  Back to cited text no. 3
[PUBMED]    
4.Cordaro L, di Torresanto VM, Petricevic N, Jornet PR, Torsello F. Single unit attachments improve peri-implant soft tissue conditions in mandibular overdentures supported by four implants. Clin Oral Implants Res 2013;24:536-42.  Back to cited text no. 4
[PUBMED]    
5.Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J Prosthodont 2012;25:392-4.  Back to cited text no. 5
[PUBMED]    
6.Cakarer S, Can T, Yaltirik M, Keskin C. Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal 2011;16:e953-9.  Back to cited text no. 6
[PUBMED]    
7.El-Sheikh AM, Shihabuddin OF, Ghoraba SM. Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: A two-year prospective study. Int J Dent 2012;2012:285684.  Back to cited text no. 7
[PUBMED]    
8.Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: A review of the literature. Int J Prosthodont 1998;11:408-20.  Back to cited text no. 8
[PUBMED]    
9.Stellingsma K, Raghoebar GM, Meijer HJ, Stegenga B. The extremely resorbed mandible: A comparative prospective study of 2-year results with 3 treatment strategies. Int J Oral Maxillofac Implants 2004;19:563-77.  Back to cited text no. 9
[PUBMED]    
10.Jackson BJ. Effective denture stabilization in an atrophic mandible. Dent Today 2012;31:130, 132-3.  Back to cited text no. 10
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]


This article has been cited by
1 Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients
Nada El Osta,Lana El Osta,Farah Moukaddem,Tatiana Papazian,Robert Saad,Martine Hennequin,Lydia Rabbaa Khabbaz
Clinical Nutrition ESPEN. 2017;
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed1808    
    Printed42    
    Emailed2    
    PDF Downloaded293    
    Comments [Add]    
    Cited by others 1    

Recommend this journal