CASE REPORT
Year : 2013  |  Volume : 4  |  Issue : 1  |  Page : 112-115  

Aesthetic rehabilitation with multiple loop connectors


Division of Prosthodontics, Army Dental Centre, R and R Delhi Cantt, New Delhi, India

Date of Web Publication9-May-2013

Correspondence Address:
Ashish Kalra
PG Resident, Division of Prosthodontics, Army Dental Centre, R and R Delhi Cantt, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0976-237X.111632

Rights and Permissions
   Abstract 

Patients with a missing tooth along with diastema have limited treatment options to restore the edentulous space. The use of a conventional fixed partial denture (FPD) to replace the missing tooth may result in too wide anterior teeth leading to poor esthetics. The diastema resulting from the missing central incisors can be managed with implant-supported prosthesis or FPD with loop connectors. An old lady reported with chief complaints of missing upper anterior teeth due to trauma. Her past dental history revealed that she was having generalized spacing between her upper anterior teeth. Considering her esthetic requirement of maintaining the diastema between 12, 11, 22, and 21, the treatment option of 06 units porcelain fused to metal FPD from canine to canine with intermittent loop connectors between 21, 22, 11, 12 was planned. Connectors basically link different parts of FPDs. The modified FPD with loop connectors enhanced the natural appearance of the restoration, maintained the diastemas and the proper emergence profile, and preserve the remaining tooth structure of abutment teeth. This clinical report discussed a method for fabrication of a modified FPD with loop connectors to restore the wide span created by missing central incisors.

Keywords: Loop, diastema, connector, eduntulous space, fixed partial denture, spacing


How to cite this article:
Kalra A, Gowda ME, Verma K. Aesthetic rehabilitation with multiple loop connectors. Contemp Clin Dent 2013;4:112-5

How to cite this URL:
Kalra A, Gowda ME, Verma K. Aesthetic rehabilitation with multiple loop connectors. Contemp Clin Dent [serial online] 2013 [cited 2020 Sep 26];4:112-5. Available from: http://www.contempclindent.org/text.asp?2013/4/1/112/111632


   Introduction Top


Patients with a missing tooth along with diastema have limited treatment options to restore the edentulous space. The use of a conventional fixed partial denture (FPD) to replace the missing tooth may result in too wide anterior teeth, an over-contoured emergence profile, which in turn causes poor esthetics. The diastema resulting from the missing central incisors can be managed with implant-supported prosthesis or FPD with loop connectors. [1],[2],[3] However, severe diastema and multiple missing teeth with long span may create esthetic problems. Maximum esthetic results may be obtained if the natural anatomic forms of teeth are protected and the diastema are maintained with minimal over-contouring of the adjacent teeth. [4] Implant-supported prostheses may be used in the oral rehabilitation of partially edentulous patients but may be expensive and time consuming for patients with requirements of many favorable local and medical factors for successful treatment option. [5],[6] This clinical report describes a technique to fabricate a 06 unit FPD with a modified palatal loop connector to provide maximum esthetic and functional correction for a patient with diastema between lateral and central incisor and missing central incisors.


   Case Report Top


A 35-year-old lady reported with chief complaints of missing upper anterior teeth due to trauma. The maxillary laterals incisors and canines on both sides had endodontic treatment post trauma but had good periodontal support. Her past dental history revealed that she was having generalized spacing between her upper anterior teeth and her medical history was non-contributory. Clinical and radiological examination revealed the endodontically treated 12, 13, 22, 23, missing 11, 2, less amount of bone available in upper anterior region and traumatic bite because of supra eruption of lower anterior teeth [Figure 1] and [Figure 2]. The treatment options included an implant-supported prosthesis, FPD with loop connectors, resin bonded FPD. Considering her availability of bone and esthetic requirement of maintaining the diastema between 12, 11, 22, and 21, the treatment option of 06 units porcelain fused to metal FPD from canine to canine with intermittent loop connectors between 21, 22, 11, 12 was planned.
Figure 1: Preoperative picture showing missing teeth

Click here to view
Figure 2: Extraoral picture showing missing teeth

Click here to view


The following clinical and lab procedures were carried out for her oral rehabilitation:

Teeth preparation for porcelain fused to metal was done on 12, 13, 22 and 23. Maxillary anterior FPD with loop connectors may cause occlusal interferences because of limited interocclusal space. In this patient, enameloplasty of lower anterior teeth was done to regain the interocclusal space and to prevent the interferences. The shoulder finish lines of the preparation were kept equigingival in order to enhance the esthetics as it prevents the color of the metal from showing thorough translucent enamel. [7] Final impressions were made with two stage double mix putty light body rubber base impression material (Aquasil, Denstply) [Figure 3] and poured in Type IV dental stone (Bego stone; BEGO, Bremen, Germany). Master casts were retrieved and die cutting was done. A quick-setting rigid poly vinylsiloxane interocclusal registration material was used to record the maxillomandibular relationship. The provisional FPD was fabricated and cemented using non-eugenol cement [Figure 4]. Casts were mounted on a semi-adjustable articulator (Hanau H2) using a face-bow transfer. A 0.5 mm thick wax sheet was placed on the edentulous ridge to create a space to allow convenient access for oral hygiene. Patterns of the modified FPD with loop connectors were fabricated by using blue inlay wax indirectly on the cast, adjusted for optimal occlusal contacts, and contoured to final shape, and form [Figure 5]. The patterns were invested with a phosphate-bonded investment (Bellawest, BEGO) and cast in a base metal alloy (Wiron 99; BEGO). After confirming the metal try in, the porcelain (Vita, Germany) was fired according to the manufacturer's recommendations. Pontics were contoured with a fine-grained bur maintaining the diastemas and evaluated for esthetics and residual ridge adaptation [Figure 6]. The occlusion was evaluated and adjusted where necessary. After glazing and polishing, the intaglio surface of the retainers was sandblasted using airborne-particle abraded with 50-mm aluminum oxide. Try in was done and interferences if any were removed. The surfaces of abutment teeth were steam cleaned and the restorations were cemented with Glass ionomer cement (GIC) Type I luting cement [Figure 7] and [Figure 8]. This prosthesis design may decrease access for plaque removal because palatal connectors are over-contoured by design. The patient was instructed to maintain the proper oral hygiene. Use of dental floss (Superfloss; Oral B, UK) and interdental brush (Interdental; Oral B) were recommended. The patient was evaluated after 1 week to assess the oral hygiene status.
Figure 3: The final impression of the prepared teeth

Click here to view
Figure 4: The cemented provisional crown

Click here to view
Figure 5: The wax up for 06 units bridge with loop connectors

Click here to view
Figure 6: The final prosthesis

Click here to view
Figure 7: The FPD cemented in mouth

Click here to view
Figure 8: The FPD cemented in mouth

Click here to view



   Discussion Top


Connectors basically link different parts of FPD (i.e., pontic and retainers). Thus constitute an important part of FPD. Their designing determines the health of periodontal ligament under FPD. They may be either rigid or non-rigid. The presence of the missing central incisors with a wide span is a difficult esthetic problem to resolve with conventional FPDs. The modified FPD with loop connectors enhance the natural appearance of the restoration, maintain the diastemas and the proper emergence profile, and preserve the remaining tooth structure of abutment teeth. However, this type of prosthesis requires additional laboratory procedures. In addition, the prosthesis design may cause difficulty in maintenance and may affect in phonetics especially linguopalatal sounds. However keeping the connectors round and small in size will not affect the phonetics.

Photoelastic analysis has revealed that within the connector, the highest stress was found at the gingival region of the connector and the lowest in the middle of the connector. [8],[9] Also, connector geometry affects the strength of ceramic materials. [10],[11] Therefore, smoother, less angled and more round connectors should be kept for lower stress levels. [12]


   Summary Top


This clinical report discussed a method for fabrication of a modified FPD with loop connectors to restore the wide span created by missing central incisors. The full coverage PFM crowns were fabricated for abutments to preserve them. This prosthesis resulted in an esthetic result and required minimal adjustments.

 
   References Top

1.Miller TE. Implications of congenitally missing teeth: Orthodontic and restorative procedures in the adult patient. J Prosthet Dent 1995;73:115-22.  Back to cited text no. 1
    
2.Melsen B. Current controversies in orthodontics. Chicago: Quintessence; 1991. p. 254-6.  Back to cited text no. 2
    
3.Moyers RE. Handbook of Orthodontics. 4 th ed. St. Louis: Mosby; 1988. p. 348-60.  Back to cited text no. 3
    
4.Bello A, Jarvis RH. A review of esthetic alternatives for the restoration of anterior teeth. J Prosthet Dent 1997;78:437-40.  Back to cited text no. 4
    
5.Olson JW, Shernoff AF, Tarlow JL, Colwell JA, Scheetz JP, Bingham SF. Dental endosseous implant assessments in a type 2 diabetic population: A prospective study. Int J Oral Maxillofac Implants 2000;15:811-8.  Back to cited text no. 5
    
6.August M, Chung K, Chang Y, Glowacki J. Influence of estrogen status on endosseous implant osseointegration. J Oral Maxillofac Surg 2001;59:1285-9.  Back to cited text no. 6
    
7.Eshleman JR, Janus CE, Jones CR. Tooth preparation designs for resin-bonded fixed partial dentures related to enamel thickness. J Prosthet Dent 1988;60:18-22.  Back to cited text no. 7
    
8.Kou W, Kou S, Liu H, Sjögren G. Numerical modeling of the fracture process in a three-unit all-ceramic fixed partial denture. Dent Mater 2007;23:1042-9.  Back to cited text no. 8
    
9.Oh W, Götzen N, Anusavice KJ. Influence of connector design on fracture probability of ceramic fixed-partial dentures. J Dent Res 2002;81:623-7.  Back to cited text no. 9
    
10.Kamposiora P, Papavasiliou G, Bayne SC, Felton DA. Stress concentration in all-ceramic posterior fixed partial dentures. Quintessence Int 1996;27:701-6.  Back to cited text no. 10
    
11.Fischer H, Weber M, Marx R. Lifetime prediction of all-ceramic bridges by computational methods. J Dent Res 2003;82:238-42.  Back to cited text no. 11
    
12.Plengsombut K, Brewer JD, Monaco EA Jr, Davis EL. Effect of two connector designs on the fracture resistance of all-ceramic core materials for fixed dental prostheses. J Prosthet Dent 2009;101:166-73.  Back to cited text no. 12
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
   Summary
    References
    Article Figures

 Article Access Statistics
    Viewed4294    
    Printed43    
    Emailed0    
    PDF Downloaded381    
    Comments [Add]    

Recommend this journal