Contemporary Clinical Dentistry
   
  Home | About us | Editorial board | Search
Ahead of print | Current Issue | Archives | Advertise
Instructions | Online submission| Contact us | Subscribe |

 

Login  | Users Online: 371  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 



 
 Table of Contents  
CASE REPORT
Year : 2012  |  Volume : 3  |  Issue : 6  |  Page : 219-222  

Immediate placement of implant in fresh extraction socket with early loading


Department of Prosthodontics, Faculty of Dental Sciences, IMS, Banaras Hindu University, Varanasi, Uttar Pradesh, India

Date of Web Publication18-Sep-2012

Correspondence Address:
Archana Singh
Department of Prosthodontics, Faculty of Dental Sciences, IMS, BHU, Varanasi- 221 005, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0976-237X.101099

Rights and Permissions
   Abstract 

Implant placement in maxillary anterior region has most aesthetic challenges in implant dentistry because tooth loss lead to bone resorption and collapse of gingival architecture, which lead to aesthetic compromise and inadequate bone for implant placement. Immediate implant placement into fresh extraction socket reduces the treatment time, cost, preserved the gingival aesthetic and increases the comfort of the patient. This article describes the procedure for immediate implant placement in fresh extraction socket and early loading of implant with zirconia crown. Clinical and radiographic examination revealed width and length of the tooth for selecting implant size and design. Cement retained zirconia crown was used for early loading. Implant was successfully loaded and was functional during 36 months follow up period. Immediate placement and early loading of dental implant provides advantages like fewer surgical procedures, shorter treatment time, and improved aesthetic and psychological confidence.

Keywords: Early loading, fresh extraction socket, and gingival architecture immediate placement


How to cite this article:
Singh A, Gupta A, Yadav A, Chaturvedi T P, Bhatnagar A, Singh B P. Immediate placement of implant in fresh extraction socket with early loading. Contemp Clin Dent 2012;3, Suppl S2:219-22

How to cite this URL:
Singh A, Gupta A, Yadav A, Chaturvedi T P, Bhatnagar A, Singh B P. Immediate placement of implant in fresh extraction socket with early loading. Contemp Clin Dent [serial online] 2012 [cited 2020 Apr 2];3, Suppl S2:219-22. Available from: http://www.contempclindent.org/text.asp?2012/3/6/219/101099


   Introduction Top


Loss of tooth in the aesthetic zone is a traumatic experience with or without compromise in phonetics. Hence, in the aesthetic zone implant supported single tooth replacement is one of the most challenging situations confronting the clinician.

According to the traditional protocols 3-4 months of healing period is required for the consolidation of extraction socket. Taking into account the prosthetic treatment, patients frequently are required to wait up to 1 year for replacement of a lost tooth. [1]

Attempts to shorten the overall length of treatment period have focussed on approaches like early or immediate loading following implant placement, immediate implant placement in fresh extraction site, and immediate implant placement and early or immediate loading. [2],[3],[4]

The concept of immediate implant loading has recently become popular due to less trauma, reduction in overall treatment time, decrease in hard and soft tissue resorption, increase in patient's acceptance, along with better function, aesthetics and has a psychological benefit also. [5],[6] In this case report the harmony of soft and hard tissue was preserved by immediate implant placement and early loading in anterior maxilla.


   Case Report Top


A 20 year old male patient presented to the Department of Prosthodontics, Banaras Hindu University with chief complaint of fractured upper front teeth due to trauma. Clinical and radiographic examination revealed fractured tooth with unfavourable prognosis [Figure 1]. The patient was given a detailed explanation concerning the present state, alternative treatment plans and the proposed procedure which included immediate implant placement and early loading. The patient was very conscious about his aesthetic and was very keen for earliest possible restoration of his teeth and so he opted for proposed procedure.

Pre-surgical radiographic evaluation was carried out with IOPA, panoramic radiograph and CT Dentascan [Figure 2] for appropriate treatment planning. In CT Dentascan diameter of the socket 1mm apical to crestal bone was 5 mm and length of the socket was 10.5 mm.
Figure 1: Pre-operative occlusal view of fractured maxillary left central incisor

Click here to view
Figure 2: Pre-operative CT Dentascan showing sub gingival fracture in maxillary left central incisor and computed tomogram viewed before operation

Click here to view


After proper treatment planning endo-osseous implant (Hi-Tec tapered self threaded, Life Care Devices Private Limited, Isreal) measuring 5 × 13 mm in dimension was selected. Following an injection of 2% lidocaine with 1: 100,000 epinephrine local anaesthetics, the fracture tooth was atraumatically removed [Figure 3]. The resulting extraction socket was evaluated for osseous defects. All four walls were found intact. The extraction socket was thoroughly debrided and after sequential drilling implant was placed in socket with the insertion torque of 45 Ncm [Figure 4]. Implant first thread was placed 1.5 mm apical to crestal bone of the socket and adequate primary stability was obtained. Post-operative periapical radiograph was taken [Figure 5] Impression is made by open window tray technique using vinyl polysiloxane impression material (Aquasil, Dentsply/Caulk, Milford, DE). Healing cap (Hi-Tec HC-3 gingival former Life Care Device Private limited, Isreal) was secured on the implant. Appropriate antibiotic (amoxicillin 500 mg, 3 times daily for 7 days) and analgesic (ibuprofen 800 mg, every 4 to 6 hours as needed) were prescribed and post operative instructions were given. The impression was poured with type-IV stone (Ultrarock, Kalabhai Karson Pvt.Ltd., Mumbai). The master cast obtained was mounted on a semi adjustable articulator. The abutment was prepared outside the mouth on the working cast. The working cast was then sent to laboratory for fabrication of CERCON® Zirconia crown (Dentsply Ceramco, York, PA).
Figure 3: Atraumatic tooth extraction without flap reflection resulted in well preserved bone and soft tissue architecture

Click here to view
Figure 4: A 5 × 13 mm tapered self-threaded implant (Hi-tech, Lifecare devices private limited, Isreal) was inserted to desired depth after sequential osteotomy

Click here to view
Figure 5: Periapical radiograph after implant surgery

Click here to view


After 2 weeks of healing period, the implant was loaded with cement retained Zirconia crown [Figure 6], [Figure 7]. Follow up was done at 6, 12, 18 and 36 months subsequently [Figure 8].
Figure 6: The definitive customized abutment with corresponding gingival emergence were tightened to 35 Ncm torque

Click here to view
Figure 7: Labial view of defi nitive implant zirconia restoration. Figure 8: IOPA 3 year after the implant surgery Note- The preservation of tissue architecture and minimal trauma to surrounding tissue

Click here to view
Figure 8: IOPA 3 year after the implant surgery

Click here to view



   Discussion Top


Immediate implant and early loading may be a good treatment option in the loss of anterior teeth. [4] Its success rate in maxilla is 66%-95.5% and in mandible 90%-100%. [7]

Immediate implant placement is most commonly indicated when tooth extraction is due to trauma, endodontic lesion, root fracture, root resorption, root perforation, unfavourable crown to root ratio (not due to periodontal loss) and bony walls of alveolus are still intact. [8] Contraindications includes presence of active infection, insufficient bone (<3 mm) beyond the tooth socket apex for initial implant stability and wide and/or long gingival recession.

Prior to extraction of tooth it was aesthetically evaluated to comprehensively assess the potential implant placement site. A proper plan was made which included soft tissue treatment protocol and set of well defined aesthetic goals. Under three parameters the prospective implant site was evaluated to predict the peri-implant aesthetic outcome these are tooth position and shape, form and bio-type of the periodontium and position of osseous crest. [9]

The surgeon may wish to consider loading the newly placed implant immediately or early when anyone of the following condition exist at implant site: when primary stability is obtained, bone is type I or II, site can accommodate implant with a length of at least 13 mm or minimum 3 mm of apical bone present, diameter of the head of the implant closely matches the mesio-distal with of coronal aspect of the socket, no need for bone augmentation procedure, once placed the implant can be completely protected from function and occlusal forces. [10]

The initial stability of the implant is essential for early/immediate loading. The minimum insertion screw has to be equal or superior to 32 N/cm and the micro movement of the implant should not exceed 150 um. Bruxism and the lack of primary stability of the implants are contraindications for the immediate loading. [7],[11] In this case report, primary stability was achieved and no need for bone augmentation because the implant diameter closely matches the socket dimension.

Immediate/early loading of implant requires an understanding of the biology of the recipient tissue, the surgical trauma, the wound healing process and occlusion. Wound healing studies have demonstrated that early osteoid formation begins after 7 day, mineralization commences at 21 days thus implant loading after 2-3 weeks may therefore turn into a feasible protocol. [12] In this case report implant is loaded after 2 week and during 3 year of follow-up there is minimum bone loss occur.

Dental implants that are immediately placed and loaded into carefully selected extraction socket have high survival rates comparable to implant placed in healed site. [5]

In this case report we are pleased with the gingival aesthetic. Studies have confirmed that immediate loading will produce excellent gingival aesthetics. Although in this study only two patient visits were needed to achieve this result, our real goal is to show the potential to reduce time and improve patient satisfaction.


   Conclusion Top


This case report demonstrates that it is possible to achieve greater efficiency in our efforts to give patient sound, timely and economical treatment. This procedure is still technique sensitive, but it is clear that with continued innovation in the prosthetic capabilities of implant system we should be able to enhance the service and treatment offered to our patients in regard to our treatment time, patient comfort, cost and aesthetics.

 
   References Top

1.Brånemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses, I: Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100.  Back to cited text no. 1
    
2.Flanagan D. Immediate placement of multiple mini dental implants into fresh extraction sites: A case report. J Oral Implantol 2008;34:107-10.  Back to cited text no. 2
    
3.De Rouck T, Collys K, Cosyn J. Immediate single tooth implants in the anterior maxilla: A 1-year case cohort study on hard and soft tissue response. J Clin Periodontol 2008;35:897-904.  Back to cited text no. 3
    
4.Ataullah K, Chee LF, Peng LL, Tho CY, Wei WC, Baig MR. Implant placement in extraction sockets: A short review of the literature and presentation of a series of three cases. J Oral Implantol 2008;34:97-106.  Back to cited text no. 4
    
5.Schropp L, Kostopoulos L, Wenzel A. Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: A prospective clinical study. Int J Oral Maxillofac Implants 2003;18:189-99.  Back to cited text no. 5
    
6.Quirynen M, Van Assche N, Botticelli D, Berglundh T. How does the timing of implant placement to extraction affect outcome? Int J Oral Maxillofac Implants 2007;22 (Suppl):203-23.  Back to cited text no. 6
    
7.Uribe R, Peñarrocha M, Balaguer J, Fulgueiras N. Immediate loading in oral implants. Present situation. Med Oral Patol Oral Cir Bucal 2005;10 (Suppl 2):E143-53.  Back to cited text no. 7
    
8.Douglass GL, Merin RL. The immediate dental implant. J California Dent Assoc 2002;30:362-5.  Back to cited text no. 8
    
9.Paolantonio M, Dolci M, Scarano A, D'Archivio D, Di Placido G, Tumini V, et al. Immediate Implantation in Fresh Extraction socket: A Controlled Clinical and Histological study in man. J Periodontol 2001;72:1560-71.  Back to cited text no. 9
    
10.Hahn J, Babbush CA. Dental implants: The art and science. Immediate implant placement after extraction: Contemporary materials and techniques. 2 nd ed. United States of America: W.B. Saunders; 2001. p. 305-34.  Back to cited text no. 10
    
11.McNutt MD, Chou CH. Current trends in immediate osseous dental implant case selection criteria. J Dent Edu 2003;67:850-9.  Back to cited text no. 11
    
12.Schwartz Z, Boyan BD. Underlying mechanism of the bone-biomaterial interface. J Cell Biochem 1994;56:340-7.  Back to cited text no. 12
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed3139    
    Printed87    
    Emailed3    
    PDF Downloaded428    
    Comments [Add]    